Water Treatment
Ozone and oxygen for sustainable odour and corrosion control
1st July 2019
By Paul Turgeon, CEO and Tonya Chandler, VP Sales & Marketing at Anue Water Technologies
Sustainable oxygen and ozone help improve safety and decrease costly equipment damage, says Paul Turgeon, CEO and Tonya Chandler,
Sustainable oxygen and ozone help improve safety and decrease costly equipment damage, says Paul Turgeon, CEO and Tonya Chandler, VP Sales & Marketing at Anue Water Technologies.
Wastewater systems have long been subject to issues with odour and corrosion, which is understandable given the nature of what they convey. The odour is the driving force behind implementing controls for these systems. Corrosion, however, is the issue with the greatest potential for environmental harm and real systemic and economic damage. This damage can arise in the form of burst pipes and other equipment and system failures.
Failures of this type require the repair and replacement of system materials and equipment, and they have the potential to expose the environment to unpredictable releases of hazardous waste that are difficult, if not impossible, to contain or recover.
Corrosion caused by H2S
A major contributor to odour and corrosion in industrial systems is hydrogen sulfide (H2S) and its associated compounds. Some industrial wastewater contains sulfur compounds, which provide the molecular basis for the generation of H2S. H2S arises from the combination of anaerobic conditions and the presence of sulfites and sulfates in conjunction with colonies of microorganisms present on the inner walls of all collection systems, referred to as the slime layer. Sulfate reducing bacteria (SRB) will use these compounds in the absence of free oxygen (O2) for metabolism. These bacteria do not use the sulfur component, and it is available to react with water, specifically free protons (H+), which results in the generation of H2S.
Following its generation, H2S can be released into the atmosphere and find its way to receptors through junctions of the atmosphere and collection system, at which point it is an odour concern. H2S is a colourless gas that has a characteristic ‘rotten egg’ odour, is highly toxic and is corrosive to certain metals. It is heavier than air, meaning it can accumulate in wells, manholes and other locations that do not have much ventilation.
H2S becomes a corrosion issue when it contacts moist concrete or steel (among other metals) in the presence of oxygen, even at very low gaseous concentrations. Conditions such as these are common in the headspace of some pipes and other areas where the collection system has easy access to atmospheric oxygen. Bacteria in these areas convert the H2S into sulfuric acid, which then begins a destructive reaction with the infrastructure.
Historically, control of odour and/or corrosion has been implemented through either vapour phase techniques, where the headspace of a system is treated, or liquid phase techniques, where treatments target the liquid flow. Vapour phase treatments like scrubbers do not provide corrosion control. Some of the liquid phase techniques offer corrosion control.
The most common method of inducing liquid phase treatment, or directly treating the wastewater inside collection systems, has been by dosing chemicals into the systems. These chemicals are meant to react with the odour-causing compounds present in the wastewater, or cease their formation and/or release.
Conventional control options
The conventional classes of reactions used to control H2 S are:
- Chemical oxidation – Chemical oxidation of H2S is accomplished through the use of a compound with a high oxidation potential, such as hydrogen peroxide or sodium hypochlorite (bleach).
- Sulfide scavengers (iron salts) – Chemicals that interact with H2S and scavenge the sulfur into a relatively insoluble form, such as ferric chloride or ferrous chloride, can be used to remove sulfur from the cycle entirely.
- pH adjustment – Because of the way that its ions dissociate in the aqueous phase, the release of H2S from wastewater will not occur if the pH is 9 or above.
In an anaerobic environment, the microbiology in a collection system will use oxygen from a nitrate (NO3) molecule more readily than from a sulfate (SO4) molecule and, as a result, benign nitrogen is released rather than H2S. Chemicals like calcium or sodium nitrate are commercially available and can be used for this purpose. However, they can be expensive, and they feed and grow the SRB layer, potentially requiring a higher volume for treatment over time. Upon cessation of treatment, the amount of H2S can be even worse than before. Increased clean-out cycles may also be required due to the addition of the waxes used to stabilize the nitrate molecules.
In addition, emerging federal and state regulations are beginning to include nitrate concentrations on discharge limitations. Real-time, active monitoring of wastewater H2S levels is seldom carried out, so enough chemical to control peak H2S values is typically added on a constant basis. By treating for peak values with chemicals such as these, the likelihood is very high that excess nitrate will be present and actively added to the wastewater, requiring additional denitrification processes or fines, both of which can be very expensive.
An issue with all chemicals is that, to introduce them to a collection system, a bulk quantity must be stored nearby. To ensure that chemicals are always available for treatment, continued deliveries to the bulk storage tank must be made. To avoid adverse effects to the environment, engineered controls, such as secondary containment and leak monitoring, must be designed, implemented and maintained.
Finding an alternative solution
Ideally, a successful treatment of wastewater odour and corrosion would:
- End sulfide production
- Quickly eliminate sulfides
- Bring about no additional hazard to life or the environment
- Do no harm to the collection system
- Create no additional challenges downstream
- Be cost effective.
One answer is the introduction of ozone and oxygen into wastewater systems to control odour and corrosion.
Ozone has long been used in water treatment, dating back at least to the late 19th century (primarily for the disinfection of drinking water),1 and ozone treatment of water is common in Europe.2 The controlled use of ozone does not produce harmful by-products – typically, the only by-products are O2 and inert oxides. In recent years, its environmental sustainability and relative safety versus chemical systems have led to renewed interest in its use to treat wastewater. This has driven the development of new and sustainable (green) technology for odour and corrosion control.
Ozone is a special, naturally occurring form of atmospheric oxygen. Instead of two oxygen atoms it has three, represented by its chemical formula O3. This third oxygen atom makes it a highly reactive molecule with very high oxidation potential. In fact, it has the highest oxidation potential of any commercially available molecule, and the fourth highest overall with an oxidation potential of 2.07 volts (V). Above it, in terms of oxidation potential, are atomic fluorine (F•, 2.87 V), the hydroxyl radical (•OH, 2.86 V) and atomic oxygen (O•, 2.42 V). Ozone can be generated by exciting a flow of oxygen with sufficient electrical or optical energy. This will cause a certain amount of oxygen atoms to split and recombine with other O2 molecules nearby.
3